
![]() |
Special Offers
The following used systems and components are for sale. These items have to be refurbished before resale, therefore the delivery time will probably be 2 months. If you have any questions, please contact our service persons:
Klaus Bohländer (Germany, Austria, Switzerland):
Tel. +49 721 595 6289
E-mail klaus.bohlaender@bruker-axs.de
Sonja Heinecke (all other countries):
Tel +49 721 595 3305
E-mail: sonja.heinecke@bruker-axs.de
Systems
| CRYSTAL FARM IMAGING SYSTEM 240VAC/50Hz | Location: Delft |
| Specification: 862-091600 | |
| Environmentally controlled, web-based, automated plate handling, incubation, and imaging system. Modular networkable system for multi temperatures/conditions. | |
| The system includes: | |
| - Imager | |
| - Incubator | |
| - Crystal Farm Navigator | |
| - System includes complete windows based web server with 500GB of RAID-5 disk storage and all Crystal Farm software preinstalled and preconfigured | |
| - 6 Month warranty | |
| - ex Works, Delft | |
| -For more information and prices, please contact the above mentioned service persons. |
Components
| Kryo-Flex Low Temperature Equipment | Location: Delft |
| Specification: BRU-W1101358 | |
| Low-Consumption and highly stable low-Temperature device based on a heat-exchanger principle | |
| - Temperature range of < 90 K to 300 K | |
| - Stability of +/- 0.1 K | |
| - Nitrogen consumption < 0.5l/hr | |
| - Electronic, user controlled gas-flow-rate | |
| - 3000 mm flexible transfer line; will pass through D8 labyrinth | |
| - Extremely quiet pump as 19.-rack unit | |
| - Control electronics as 19.-rack unit | |
| - Safety features to check for Nitrogen gas flow present and dewar low level | |
| - 60 l dewar included for 5 days autonomous operation | |
| - Automatic refill from optional supply dewar | |
| - Software control | |
| - Verification of the temperature in close vicinity of the sample position | |
| - Nozzle with secondary dry air stream to avoid icing (needs supply of dry compressed air; dew point -60C; 2 bar; 5 l/min) | |
| For more information and prices, please contact the above mentioned service persons. |
| KRYO-FLEX Support for KAPPA APEXII X8PROTEUM and X8APEX sealed tube systems | Location: Delft |
| For mounting the KryoFLex LT device in a vertical position over the centre of a four-axis Kappa Goniometer | |
| - Mounts easily on the back of the Kappa Goniometer | |
| - Not suitable for CAD4, MACH3 and KAPPACCD goniometers | |
| - Can be positioned freely in a groove around the goniometer centre | |
| - Fine adjustment in the XY plane | |
| - Fast displacement in Z for easy sample mounting and fast cooling | |
| For more information and prices, please contact the above mentioned service persons. |
Ni/C PUSH-PLUG GÖBEL MIRROR FOR D8 60 mm LENGTH
Location: Karlsruhe
FOR Cu RADIATION, Part No. A18B46
Graded multilayer optics for Cu radiation, including optical element, housing and slits.
The parabolic bent Göbel Mirror creates a highly parallel incident beam while suppressing Kbradiation. Ni/C is the optimum material combination for the multilayer, because the natural CuKß absorber is implemented. By capturing a large solid angle, the mirror turns otherwise unusable radiation into a useful parallel beam.
The Göbel Mirror enables the investigation of irregularly shaped sample surfaces and reduces the requirements for exact sample positioning.
Ideal for samples with low X-ray absorption. Considerable intensity gain for parallel-beam applications such as grazing incidence diffraction and reflectometry. A Cu long fine focus Xray tube is recommended for use with this optic.
Price: 17.500,-- €
| Transfer line heater for KryoFlex | Location: Karlsruhe |
| Specification: BRU-W1101412 | |
| Maintenance tool for the KryoFlex low temperature device. | |
| Transfer-Line Heater will support the repumping of the KryoFlex vacuum by controlled heating of the transfer-line. | |
| Price: | € 1.950,-- |
| Air Dryer for LT Devices | Location: Karlsruhe |
| Specification: DLT-Z-KM5-FLTR | |
| Compact self-regenerating absorption dryer for the warm envelop gas stream of the LT3 or KryoFlex. Requires 6 bar compressed air (or nitrogen). | |
| - Absorbance: 2 x 1.7 kg Ecosorb | |
| - Gas temperature to be < 25ºC | |
| - Dew point -70ºC | |
| - Max. capacity of 5 m3/h | |
| - Includes noise-reduction filter | |
| - Connection of type G¼ | |
| - 230 V; 50/60 Hz | |
| - overall size 305 x 327 x 180 mm (hwd); weight: 8.9 kg | |
| - incl. 10 m polyurethane tubing (8mm out; 5.5mm in), 2 - 90°-quick-connectors and 1 adapter for compressor | |
| Price: | € 1750,-- |
| Goebel Mirror | Location: Karlsruhe |
| Specification: | Cu, 2nd Generation; 40 mm |
| Part No.: | C79298-A3161-D210 |
| Price: | € 12.500,-- |
| Goebel Mirror | Location: Karlsruhe |
| Specification: | Co, 2nd Generation; 40 mm |
| Part No.:: | C79298-A3161-D112 |
| Price: | € 15.000,-- |
| Goebel Mirror | Location: Karlsruhe |
| Specifications: | Cu, 2nd Generation; 40 mm |
| Part No.: | C79298-A3161-D106 |
| Price: | € 15.000,-- |
| Goebel Mirror | Location: Karlsruhe |
| Specifications: | Cu, 3rd Generation; 40 mm |
| Part No.: | C79298-A3161-D213 |
| Price: | € 17.000,-- |

