Language
Search
News
- XFlash® 6 – Bruker Introduces the Next Generation of EDS Detectors
- Bruker Announces New High-Performance Scientific Instruments and Analytical Solutions for Life-Science Research, Industrial and Applied Markets at Analytica 2012
- Bruker Announces Acquisition of SkyScan, a Leading Provider of Micro-CT Systems for 3D X-Ray Imaging in Materials Research and Preclinical Studies
- New Large Area EDS Detector for Transmission Electron Microscopy
- Bruker receives Honorable Mention for Seattle Business magazine’s 2011 Washington Manufacturing Award
Upcoming Events
- OrthoTec 2012
Jun 06-07, Winona Lake, IN, USA - ACHEMA 2012
Jun 18-22, Frankfurt/M., Germany - Seeing at the Nanoscale 2012
Jul 09-11, Bristol, UK - ACA Annual Meeting
Jul 28-Aug 01, Boston, Massachusettes, USA - ACS Fall
Aug 19-21, Philadelphia, Pennsylvania, USA
ARGUS FSE/BSE detectors for e-Flash
The e–Flash detectors are now optionally available with ARGUS™ forescattered electron (FSE) and backscattered electron (BSE) detectors – e–Flash1000+ or e–FlashHR+, respectively. This further increases the versatility of the detectors and provides valuable additional information for meaningful and efficient EBSD analysis.
The set of two BSE detectors is mounted above the screen of the EBSD detector. The three FSE detectors are below the screen. This position of the detectors does not affect the performance or user-friendliness of the e–Flash, the screen remains user replaceable. All electronics required for the operation of the FSE/BSE detectors are already included in the e–Flash+ detector encasement. Apart from the convenience this also ensures that signal loss is minimized as the preamplifiers are close to the detectors.
BSE detector for improved image quality
If the EBSD detector is fully inserted the standard SEM SE and BSE detection systems tend to produce noisy images of low quality. The ARGUS™’ BSE detectors are positioned optimally to acquire the BSE signal from samples with a high tilt angle, as is the case for EBSD measurements. This includes the location above the screen and the inclination towards the sample, both of which ensure optimum signal strength. Also, the EDS detector can pass between the BSE detectors, to provide best possible conditions for simultaneous EDS and EBSD acquisition.
The ARGUS™ BSE detectors produce a density-dependent signal, similar to that by conventional SEM BSE detectors. This signal can be used individually or mixed with that from the FSE detectors.
Colorful orientation images with Bruker's ARGUS FSE detectors
Each of the three ARGUS™ FSE detectors below the EBSD screen captures a part of the diffraction signal. As this is anisotropic and dependent on crystallite orientation, it is improbable that all three of the FSE detectors will register the same signal brightness for adjacent grains. Color coding and mixing the individual detector signals produces colorful images of the grain structure. This feature is unique to Bruker’s FSE detectors. The user even has the choice to define palettes for optimum sample representation.
These images prove very helpful for subsequent EBSD analysis. The clarity of the image indicates the quality of sample preparation. Moreover, these images can be used to judge the microstructure of the sample and to determine areas most interesting or representative for the actual EBSD analysis, as well as for an extremely fast analysis of heterogeneities in the microstructure.